Dongguan Chengfeng Testing Equipment Co., Ltd

Dongguan Chengfeng Testing Equipment Co., Ltd Establish credibility with sincerity and strive for excellence with sharpness! 以诚立信,以锋致精!

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Fire Retardant Tester /

GB/T10295-2008 Thermal Conductivity Tester Plate Method For Dry Specimens Of Clay And Sand

Contact Now
Dongguan Chengfeng Testing Equipment Co., Ltd
Visit Website
City:dongguan
Country/Region:china
Contact Person:MissMia Feng
Contact Now

GB/T10295-2008 Thermal Conductivity Tester Plate Method For Dry Specimens Of Clay And Sand

Ask Latest Price
Video Channel
Price :US$2000-$30000
Place of Origin :China
Brand Name :CHENGFENG
Certification :ISO,CE
MOQ :1 Set
Packaging Details :Wooden cases
Delivery Time :10 Work Days
Payment Terms :T/T,Cash,L/C,Western Union,MoneyGram
Supply Ability :5 units per month
warranty :1 Year
customized support :OEM, ODM, OBM, Software reengineering
model number :CF8377A
Standard :GB/T10295-2008
Thermal conductivity range :0.015-400W/mk
Hot surface temperature :room temperature -99.99 °C
Cold surface temperature :room temperature
Plexiglass windshield :used to directly observe the experimental process
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
GB/T10295-2008 Thermal Conductivity Tester Plate Method For Dry Specimens Of Clay And Sand
Specification
Scope of application
Applicable to: thermal conductivity of dry specimens of clay and sand, and the thermal resistance of the specimen should be greater than 0.1m2.K/W.
Meet the standards
It conforms to GB/T10295-2008 "Determination of Steady-state Thermal Resistance and Related Characteristics of Thermal Insulation Materials" and ISO/DIS8301 "Determination of Steady-State Thermal Resistance and Related Characteristics ---- Heat Flow Meter Device".
Main technical parameters
1. Thermal conductivity range: 0.015-400W/mk, accuracy better than 5%.
(Equipped with a round specimen tube for geotechnical measurement, Ф90mm)
2. Hot surface temperature: room temperature -99.99 °C, temperature measurement by high-degree digital display, 0.2 grade accuracy, resolution 0.01 °C.
3. Cold surface temperature: room temperature, using a high-degree digital display to measure the temperature, 0.2 grade accuracy,
resolution 0.01 °C.
4. Hot surface temperature control: room temperature -99.99 °C, temperature measurement by high-degree program-controlled digital display, 0.2 level accuracy, resolution 0.01 °C, plate heater, two-way thyristor control.
5. The cold noodles are forced air cooling.
6. Adopt computer automatic test.
7. WPY heat flux meter is adopted, and the heat flux parameter is 23.26w/m2.mV.
8. Plexiglass windshield is used to directly observe the experimental process.
9. Heat transfer area of hot and cold plates: 150×150 (mm).
10. Adjustable spacing between hot and cold plates: 0-160 (mm).
Introduction
The thermal conductivity and thermal resistance of clay and sand are detected by a heat flow meter, and the automatic detection is realized by connecting to the computer to generate an experimental report. The thermal conductivity and thermal resistance are calculated by adding a stable hot surface temperature to one side of the specimen, transferring heat through the specimen to the cold surface (room temperature), and measuring the heat flow transferred. It is specially equipped with geotechnical sample barrel and specific heat capacity testing device, which can be used for thermal conductivity analysis and specific heat capacity determination of clay, sand and other soils.
1. Unique selling point: 15 years of professional research and development, only solving problems for customers.
2. Professional team: A technical research and development team with 12 years of experience, leading in professional knowledge and practical skills.
3. Quality assurance: The company strictly controls quality standards, meets customer standard requirements, and exceeds customer expectations.
4. Innovation ability: Develop products that meet customer needs, and years of experience make product development forward-looking and leading.
5. Competitive advantages: reliable quality, flexible and applicable equipment performance, reasonable equipment prices, high delivery speed, and guaranteed customer after-sales service.
6. Provide customized solutions for customers: fully understand customer needs, provide personalized solutions, and completely solve customer problems.
7. Reliability and credibility: The company operates steadily for a long time, winning the long-term trust of customers and solving their concerns.
Packing & Delivery
GB/T10295-2008 Thermal Conductivity Tester Plate Method For Dry Specimens Of Clay And Sand
FAQ
Q:Are you factory or trading company?
A:We are factory in Dongguan City, Guangdong Province,China.Near Shenzhen or Guangzhou.

Q:What kind of certificate you have?
A:ISO9001 Certification, CE Certification.

Q:What is the lead time of the product?
A: Generally 7-15 days after getting the deposit.

Q:How about the payment term?
A: T/T, by cash, western union, or L/C.

Q:How about the warranty term?
A:1 year warranty,The engineer can teach the machine on the spot.
Inquiry Cart 0